Question
Main panel, neutral and ground wires are on same bar. How to run neutral and ground to sub panel with separate buss bars. Also the ground bus bar in the sub panel is screwed right to the panel, does is ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
solved 0
Rick 8 months 1 Answer 263 views

Report
Question
Dom, I am replacing 2 circuit breakers with 2 arc fault breakers. I followed your youtube video and understand what I need to do to install 1st breaker. I disconnect neutral wire from neutral bar and connect to breaker. I then ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
in progress 0
Ron 8 months 1 Answer 158 views

Report
Question
My dryer stop heating up and came to realize the 30A 3prong outlet and 3prong dryer cord melted, so I removed outlet to replace and there is 4 wires rather then 3? Shouldn’t it had been a 4 prong outlet? ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
in progress 0
Samantha 8 months 1 Answer 141 views

Report
Question
I currently have a 60 amp panel with (4) fuses in my detached garage and would like to update the panel with circuit breakers and main disconnect. The feed wires are #6 copper to the existing 60 amp panel. It ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
in progress 0
Steve O 8 months 1 Answer 141 views

Report
Question
I’m swapping out my drop lights. When I cut the old one off I noticed it only had two wires...even though the reels power cord was a 3 pronged cord. The new light had a grounded cord also. Can I ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
  1. Please briefly explain why you feel this answer should be reported .

    Report Cancel
in progress 0
Larry 9 months 1 Answer 195 views

Report
Question
220v Dryer. 4 wire circuit, plug and wire to dryer terminals. 3 terminal strip (110, N, 110) plus chassis ground. There is no LOAD side wiring attached to the "N" terminal. Have found nothing disconnected that needs to attached to ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
in progress 0
patboy10us 9 months 1 Answer 209 views

Report
Question
I have a miller stick welder with a 3 prong plug that i need to convert to be able to plug it in to my 220 volt round receptical on my generator. Is there a conversion adaptor avaliable i can ...

Please briefly explain why you feel this question should be reported .

Report
Cancel
in progress 0
Dave A 9 months 1 Answer 227 views